Remote Control Commands
R&S
®
SMC100A
362Operating Manual 1411.4060.32 ─ 09
Usage: Setting only
7.16 TEST Subsystem
The TEST system contains the commands for performing selftest routines, and for
direct adjustment of the hardware assemblies (:TEST:DIRect).
The self tests return a "0" if the test is performed successfully, otherwise a value other
than "0" is returned. None of the commands of this system have an *RST value.
Improper use can destroy the assembly
The respective hardware assembly responds directly to the :TEST:DIRect command;
any safety mechanisms are bypassed. The command is intended for servicing purpo-
ses and should be used only by the Rohde & Schwarz service personnel.
:TEST<hw>:ALL:STARt.................................................................................................. 362
:TEST<hw>:ALL:RESult?................................................................................................362
:TEST<hw>:DIRect........................................................................................................ 363
:TEST<hw>:ALL:STARt
Starts a self-test on all installed hardware options.
To query the result, use the command :TEST<hw>:ALL:RESult? on page 362.
Example:
See :TEST<hw>:ALL:RESult? on page 362
Usage: Event
Manual operation: See "Start Selftest" on page 88
:TEST<hw>:ALL:RESult?
Queries the result of the performed self-test (command :TEST<hw>:ALL:STARt
on page 362).
Return values:
<Result> 0 | 1 | RUNning | STOPped
0
Success
1
Fail
*RST: STOPped
Example:
TEST:ALL:STAR
Starts the self-test
TEST:ALL:RES?
TEST Subsystem