52
Chapter 2 Modifying a Patch
Controlling the Tone
By pressing on a pad or moving your hand over the D Beam
or a ribbon, you can control the tone of other pads or
controllers.
Parameter Category: PAD CTRL
fig.2-21
Control Parameters Block Diagram
fig.2-22.e
Mute Rx: OFF, ON
Specifies how mute signals (to cut the note) will be received.
If you select ON, signals from other pads or controllers will
mute the note.
* Mute may have no effect for some sounds.
PitchRxRange: -24OFF+24, Rdm
Specifies how pitch control signals will be received. With
positive (+) settings, pitch control signals will raise the pitch.
With negative (-) settings, pitch control signals will lower the
pitch. If you select Rdm, the pitch will change randomly each
time a signal is received. If you select OFF, the pitch will not
change even if signals are received.
Ctrl Rx: OFF, ON
Specifies whether control signals other than mute, pitch, and
roll will be received. If you select ON, signals from other
pads or controllers will affect the tone.
* “MFX Ctrl” and LFO control signals are received even if this
parameter is set to “OFF.”
Roll Rx: OFF, ON
Specifies whether the sound will be repeated when [ROLL/
HOLD] is lit.
* The Controllers other than pads will be displayed as “---” and
cannot be set.
Rx Self: OFF, ON
Specifies whether or not the transmitted control signal will
itself be received.
MuteTx: OFF, ON
Specifies transmission for mute signals. If you select ON, you
will be able to cut the notes of pads or controllers.
* Mute may have no effect for some sounds.
PitchTx: OFF, ON
Specifies transmission for pitch control signals. If you select
ON, you will be able to modify the pitch of pads or
controllers.
CtrlTx: OFF, LFO Pitch, LFO Fltr, LFO Amp,
MFX Ctrl13 (Pad)
OFF, Level -, Level +, Decay -, Decay +,
Cutoff, Resonance, Color 12,
RevSend -, RevSend +, LFO Rate,
LFO Pitch, LFO Fltr, LFO Amp,
LFO Pc&Rt, LFO Ft&Rt, LFO Am&Rt,
MFX Ctrl13, RollSpeed, Tempo -,
Tempo +, TurnTable
(D Beam, Ribbon, Pedal)
Play/Stop (D Beam, Pedal)
Specifies transmission for control signals other than mute
and pitch.
Level -, Level +:
Modifies the volume.
Decay -, Decay +:
Modifies the duration (decay time.)
U0101A1 PAD CTRL
MuteRx ON
Ctrl Rx
Mute Rx
PitchRx
Range
Rx Self
+
+
Pad (D Beam, Ribbon, etc.)
Trigger
Sound
Generate
+
CtrlTxMuteTx PitchTx
Trigger
Sound
Generate
Other Pads, D Beam, Ribbons
Control
Control