Jun. 2011 JUPITER-80
Performing a Factory Reset
* Executing a factory reset causes all user data in the unit to be lost. Before you
start, refer to Data Backup and Restore Operations (p. 40) and back up
the user data.
1. Press [MENU].
The MENU screen appears.
2. Touch Factory Reset.
The Factory Reset screen appears.
3. Touch EXEC.
A confirmation message is displayed.
4. To execute the factory reset, touch OK. To quit, touch EXIT.
* The factory reset takes several minutes to finish. Be sure never to switch off the
power before the operation finishes.
When the message Completed. Please Power off! appears, the
operation has finished.
5. Switch off the power.
Updating the System
Items Required
Computer
USB memory device (256 MB or larger; recommended: M-UF2G)
Update-use file (obtained via Service Net)
Procedure
* Never switch off the power to the unit before the operation finishes. Doing so
may result in data corruption.
1. Format the USB memory device according to Formatting the USB
Memory Device (p. 40).
2. Copy the update-use file (jp80_up.bin) to the root directory of the USB
memory device.
3. Make sure the unit’s power is switched off, then connect the USB
memory device to the USB MEMORY connector at the left edge of the
Top Panel.
4. Hold down the TEMPO button and switch on the power.
5. When the message Update Mode appears, release the button.
The update starts.
* The update process takes several minutes to finish. Be sure never to switch off the
power before the operation finishes.
When the message update finished. is displayed, the operation has
finished.
6. Switch off the power.
7. Detach the USB memory device, then switch on the power to the unit and
verify that the version has been updated.
Test Mode
Items Required
USB memory device (256 MB or larger; recommended: M-UF2G)
Computer running Windows (operating system: XP, Vista or 7)
Expression pedal
MIDI cable
USB cable
Audio cable
Coaxial cable
Signal generator
Oscilloscope
Noise meter
Speakers (MA-10D, MA-15D, or other speakers equipped with coaxial
input connectors)
Headphones
MIDI keyboard and MIDI sound module
Touch pen (#00900545)
Preparations for Testing
Before starting testing, make sure that the unit’s power is not on.
1. Connect the USB memory device to the USB MEMORY connector at the
left edge of the Top Panel.
2. Set VOLUME to MAX.
3. Set AUDIO IN LEVEL (rear panel) to MAX.
Entering the Test Mode
Hold down MENU and PERC and switch on the power.
Quitting the Test Mode
Switch off the power.
Skipping Test Items
SHIFT + : This forces execution to advance to the next test item.
SHIFT + : This forces execution to return to the previous test item.
SHIFT + EXIT: This forces execution to return to 1. VERSION CHECK.
* After performing these operations, the screen takes one to two seconds to change.
Press only once, and not multiple times.