R62 / R62T / R65 / R65T - Rev. A 23
4.8 POSSIBLE FAILURES AND/OR FAULTS
We illustrate hereafter some anomalous conditions that may occur during machine operation.
Any intervention following a failure or a fault must be carried out in compliance with the
instructions, where given, and in any case after having disconnected the machine from the power.
Problem Possible causes Solutions
The machine
doesn't start
(push-button
not
illuminated)
No power
-make sure the machine is plugged in completely;
-check the guards of the electric line in the work room and
reset them, if necessary
Protection fuses
triggered
-Replace them (extraordinary maintenance)
The machine
doesn't start
(push-button
illuminated but
not flashing)
The machine is not
enabled for
operation
-Press the start push-button ref. 6 Figure 4(see paragraph
3.4.3)
One emergency
push-button has
been pressed
-reset the emergency push-button
The mobile guards
are not correctly
closed
-make sure that the guards are closed
The flour collection
drawer is not
correctly inserted
--make sure the drawer is inserted
Faulty controls
request intervention by the manufacturing company
The machine is
very noisy
Dirty scrapers
-see par. 4.10.3 CLEANING THE SCRAPERS
The machine
operates
inconsistently
Unsuitable motor
chain tension
-stretch the chains as described in par.4.4;
extraordinary
maintenance