ULTRIX-FR12 Installation Guide (v4.0) Powering the ULTRIX-FR12 31
Powering on the ULTRIX-FR12 via DashBoard
The ULTRIX-FR12 is powered on via the controlling Ultricore BCS interface.
To toggle the Ultripower Group to ON
1. Locate the Ultricore BCS node in the Tree View of DashBoard.
2. Expand the main Ultricore BCS node.
3. Expand the Ultricore BCS sub-node to display a list of sub-nodes in the Tree View.
4. Expand the Devices sub-node.
5. Double-click the Ultripower Manager sub-node.
6. Click ON.
Click OFF to power down the ULTRIX-FR12.
Caution Before setting an Ultripower Group to ON, ensure its Ultripower PSU average power output
is below 5W.
Notice The ULTRIX-FR12 does not have a physical power switch.