Programming
46 AC-F/G4x Series Installation and Programming Manual
controller can be automatically switched from Normal mode
(during office hours) to Secure mode (after office hours).
5.9.3 Auxiliary Mode 2
Auxiliary input function: Toggles Normal/Secure modes
Auxiliary output activated by: Star Button (*)
For example, in Auxiliary Mode 2, the auxiliary relay can function
as a general purpose time switch that can be activated when * is
pressed. The auxiliary setting establishes for how long the
auxiliary relay is to be activated. The auxiliary input can switch
the mode of operation of the controller between Normal and
Secure mode. By connecting a switch timer or alarm system
output to the auxiliary input, the controller can be automatically
switched from Normal mode (during office hours) to Secure
mode (after office hours).
5.9.4 Auxiliary Mode 3
Auxiliary input function: Toggles Normal/Secure modes
Auxiliary output activated by: Alarms
For example, in Auxiliary Mode 3, the auxiliary output is activated
if the controller is tampered; that is, if the case is forcibly opened
or removed from the wall. The auxiliary input can switch the
mode of operation of the controller between Normal and Secure
mode. By connecting a switch timer or alarm system output to
the auxiliary input, the controller can be automatically switched