EasyManuals Logo
Home>Rosslare>Controller>AYC-Q Series

Rosslare AYC-Q Series Installation And Programming Manual

Rosslare AYC-Q Series
63 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #59 background imageLoading...
Page #59 background image
Controller Operation
AYC-Qx4 Family Installation and Programming Manual 59
5. Enter the assignment digit for the current user slot:
1 activates the Lock Strike relay only default
2 activates the Auxiliary relay only
3 activates the Lock Strike and Auxiliary relays
If the assignment digit is valid, three beeps are heard and the
controller returns to Normal mode.
If the assignment digit is invalid, a long beep sounds and the
controller waits for another assignment digit to be entered.
5.9.17 PIN Code Length/Factory Default Settings
You must be very careful before using this command! Changing
the PIN code length also erases the entire memory contents,
including all user and special codes, and return all codes to
their factory default settings.
To change the PIN code length:
1. Enter Programming mode.
2. Select the desired PIN code length as follows:
00Returns to factory defaults and sets a 4-digit code
05Returns to factory defaults and sets a 5-digit code
06Returns to factory defaults and sets a 6-digit code
08Returns to factory defaults and sets a 4-8 digit code
When choosing the 48 option, please note that you should
either enter zeros before the code, or press # at the end (for
example if your code is 12345, enter either 00012345 or
12345#).
Both LEDs flash red.
Red
Red

Table of Contents

Other manuals for Rosslare AYC-Q Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rosslare AYC-Q Series and is the answer not in the manual?

Rosslare AYC-Q Series Specifications

General IconGeneral
BrandRosslare
ModelAYC-Q Series
CategoryController
LanguageEnglish

Related product manuals