Controller Functionality
AYC-Qx4 family manual Page 29
The way in which the two memory slots are programmed
determines a user’s access level and also determines the way in
which the AYC-Qx4 grants access in its three modes of operation.
There are three user levels:
Normal User
A Normal User only has a Primary Code and is only granted
access when the AYC-Qx4 is in Normal or Bypass Mode.
Secure User
A Secure User must have a Primary and Secondary Code
programmed; the two codes must not be the same. The Secure
User can gain access when the AYC-Qx4 is in any of its three
modes of operation. In Normal Mode the Secure User must use
their Primary Code to gain entry. In Secure Mode the Secure User
must present both their Primary and Secondary Codes in order to
gain entry.
Master User
A Master User must have both Primary and Secondary Codes
programmed with the same code. The Master User can gain
access during any mode of operation by presenting their PIN
code and/or Proximity card once to the controller. (The Master
User is convenient but is less secure than a Secure User.)

Table of Contents

Other manuals for Rosslare AYC-Q Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rosslare AYC-Q Series and is the answer not in the manual?

Rosslare AYC-Q Series Specifications

General IconGeneral
BrandRosslare
ModelAYC-Q Series
CategoryController
LanguageEnglish

Related product manuals