Controller Functionality
AYC-Qx4 family manual Page 49
Setting the Lockout Feature
In case the controller is presented with wrong codes,
consecutively several times the unit goes into lockout mode.
When a lockout occurs, the controller keypad and reader are
locked so no codes can be entered until the set lockout period
expires.
During Lockout, Mode LED is Off, Door LED flashes Red, and the
controller beeps every two seconds.
The default setting for the Lockout Feature is 4000 (Lockout
Disabled)
Note:
Using the lockout feature is highly recommended, especially
when selecting to use short PIN code length (4 or 5 digits).
1) Enter the Programming
Mode.
2) Press 6 to enter Menu 6.
The Mode LED will flash
green
3) Construct a code using the following
instructions:
Set the number of wrong code
attempts, which will cause Lockout
between 0 and 9 attempts.
Sets the Duration of the lockout,
between 00 and 99, the value is
multiplied by ten, resulting in 0-990
seconds
6
4 ? ? ?
Mode/Transmit
Door/Program
Green
Mode/Transmit
Door/Program
Green
Green

Table of Contents

Other manuals for Rosslare AYC-Q Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rosslare AYC-Q Series and is the answer not in the manual?

Rosslare AYC-Q Series Specifications

General IconGeneral
BrandRosslare
ModelAYC-Q Series
CategoryController
LanguageEnglish

Related product manuals