CALIBRATE
RUN
WARNING:
LIFT WILL NOT EQUALIZE IN CALIBRATE MODE. REMOVE ROLLING
BRIDGES BEFORE RUNNING CALIBRATE MODE. NEVER USE
CALIBRATE MODE WITH A VEHICLE ON THE LIFT. REFER TO
OPERATION INSTRUCTIONS FOR CALIBRATION STEPS
AND EMERGENCY LOWERING PROCEDURE.
NP966 Rev -
Switch Up for Run Mode
Switch And Label Inside Control Cabinet
Fig. 12
18. Close the top cover and run the lift up and
down a couple of times to verify that the
top of the runways are staying level with each
other within 1”. If the runways are not level,
re-run the calibration process by lowering the
lift to the ground and repeating the process.
19. Fasten top cover with screw.
20. Lower lift to the floor and turn the power switch
to “OFF”, Fig. 7.
21. Place the wheels free device (rolling bridge)
back into channels on the lift and fasten rubber
stops in their proper locations.