8.2) Engine back to operation
If preservation (including oil change) took place within a year of
storage, oil renewal will not be necessary. For longer storage
periods repeat preservation annually.
Step Procedure
1 Remove all plugs and caps.
2 Clean spark plugs with plastic brush and solvent.
3 Reinstall.

Table of Contents

Other manuals for Rotax 912 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rotax 912 Series and is the answer not in the manual?

Rotax 912 Series Specifications

General IconGeneral
Redline5800 rpm
TBO2000 hours
Displacement1211 cc
Bore79.5 mm
Stroke61 mm
Power Output80 hp (59.6 kW)
Compression Ratio9.0:1
Fuel TypeAvgas 100LL
Ignition SystemDual electronic ignition
Fuel SystemFuel Injected
Oil SystemDry sump
Engine Type4-cylinder, horizontally opposed, 4-stroke