17
3.3 Physical Characteristics
64.5 x 61 x 22 mm (regular housing)
95 x 76.4 x 28.8 mm (IP67 housing)
59 ± 5 g (FM-Eco4 light S)
65 ± 5 g (FM-Eco4+ light S)
148 ± 5 g (FM-Eco4+ S)
185 ± 5 g (FM-Eco4+ E S)
Internal
External (FM-Eco4+ E S only)
3.4 Technical Characteristics
3.4.1 Environmental Specifications
Operating:
-30 to +60 °C
Storage:
-40 to +65 °C
Operating: -20 to +60 °C
Battery charging: 0 to +45 °C
Battery discharging: -20 to +60 °C
Storage: -20 to +60 °C
5 % to 95 % Non-condensing
3.4.2 Electrical Specifications
Battery short circuit protection (devices with internal battery only)
Reverse polarity protection
Overcurrent protection on 1-Wire power line