7.4.3 Engine Detection and Data Collection Settings
Open the Engine detection and data collection section. Select an engine state detection method
and set the tracking accuracy. When the engine is turned on, records are generated more often.
The detected engine state is also used by other functionalities, such as driver registration.
Engine state detection
method
How the device detects whether the engine is turned on. Possible values:
Ignition (DIN4)
DIN4 is used for detection
Movement Sensor
the engine is considered to be on when
movement is detected
Custom
configure your own engine detection conditions
More info: Device Center User Manual
Default value:
Ignition (DIN4)
Location update rate
How often the device updates its location. This controls how often data is
collected and sent. Possible values:
High
at least twice a minute when driving
Medium
at least once a minute when driving
Low
at least once every two minutes when driving
Default value:
Medium
Remote blocking
Allows the engine to be blocked remotely via your fleet management
platform. It uses a constant connection to the server and increases data
consumption by up to 500 kB per month.
Default value: Off