To set up Wi-Fi manually:
1. Enter the network name.
2. Choose the security level.
3. Enter the password.
4. Press the confi rm button to connect to the Wi-Fi
connection. The product attempts to connect to
the selected network.
5. If connection is successful, a confi rmation
screen appears. Press the confi rm button to
return to the menu.
DATE/TIME SETUP
1. From the [Date/Time Setup] screen, choose the
date.
a. With [dd] highlighted, choose the day. Press the
confi rm button.
b. With [mm] highlighted, choose the month. Press
the confi rm button.
c. With [yy] highlighted, choose the year. Press the
confi rm button.
2. Choose the time.
a. With [--:] highlighted, choose the hour. Press the
confi rm button.
b. With [:--] highlighted, choose the minute. Press
the confi rm button.
3. Press the confi rm button.
MOWING ZONES
MOWING ZONE A
■ Mowing Zone A has a basic lawn layout. The lawn is
free from obstacles.
■ The robotic lawn mower can move unobstructed
from one point to another
.
■ Lay the wire 45 cm away from the perimeter edge.
MOWING ZONE B
■ Mowing Zone B has a basic lawn layout, with
obstacles.
■ The lawn is the same size as Mowing Zone A
but uses 50% more wires due to the number of
obstacles.
■ Parallel wires to and from each obstacle should
have a gap of less than 5 cm between each wire.
■ The gap between an obstacle and the perimeter
should be 90 cm minimum.
■ The gap between each obstacle should be 90 cm
minimum.
■ Lay the wire 45 cm away from the obstacles.
■ Lay the wire 45 cm away from the perimeter edge.
MOWING ZONE C
■ Mowing Zone C has an L-shaped lawn layout, with
obstacles.
■ Parallel wires to and from each obstacle should
have a gap of less than 5 cm between each wire.
■ The gap between an obstacle and the perimeter
should be 90 cm minimum.
■ The gap between each obstacle should be 90 cm
minimum.
■ Lay the wire 45 cm away from the obstacles.
■ Lay the wire 45 cm away from the perimeter edge.
MOWING ZONE D
■ Mowing Zone D has a U-shaped lawn layout, with
obstacles.
■ The two sides of the lawn are connected by a
narrow passage.
■ The narrow passage should have a width of 90 cm
minimum.
■ Lay the wire 45 cm away from the perimeter edge.
MOWING ZONE E
■ Mowing Zone E has an irregularly shaped lawn
layout, with a narrow passage in between.
■ The lawn has obstacles but has an open perimeter
(no obstacles around edges).
■ Parallel wires to and from each obstacle should
have a gap of less than 5 cm between each wire.
■ The gap between an obstacle and the perimeter
should be 90 cm minimum.
■ The gap between each obstacle should be 90 cm
minimum.
■ Lay the wire 45 cm away from the obstacles.
■ Lay the wire 45 cm away from the house.
■ Lay the wire 10 cm away from open perimeter, or
any level paving stones around the house.
MOWING ZONE F
■ Mowing Zone F has split lawns, with a narrow
passage in between.
■ Both lawns are free from obstacles.
■ The narrow passage should have a width of 90 cm
minimum.
■ Lay the wire 45 cm away from the obstacles.
■ Lay the wire 45 cm away from the perimeter edge.
MOWING ZONE G
■ Mowing Zone G has split lawns (Lawn A and Lawn
B).
■ The lawns are separate, with an obstacle in
between but with parallel wires connecting Lawn
A