To set the two free dispensing periods, it's necessary to:
Fifth main item of the
programming menu
TIME MANAGEMENT
It may be displayed as an addition to the four main items by
inserting the clock module device. Press "ENTER" to access
the change of the single functions. Press "ENTER" to access
the item functions.
FREE VEND
This function allows the setting of when and how to dispense
drinks for free.
Press "ENTER" to access the display of the methods with
which free dispensing is performed.
FREE VEND ALWAYS
FREE VEND TIME RANGE
- Press "ENTER"
- A flashing cursor appears under the letters identifying the
week days, and by pressing the "UP" and "DOWN" keys the
character changes from upper to lower case.
N.B.: "Upper case character" = enabled day; "lower case
character" = disabled day.
- Press "ENTER" to store to memory. The cursor
automatically moves to the following letter.
- Follow the same procedure to set the remaining letters.
- Press "ENTER" to confirm the new value.
- Shutdown time is asked automatically (OFF1). Repeat the
operation sequence for each time interval whose value is to
be modified.
Once the last value has been selected and confirmed with
"ENTER", start up and shutdown time are asked for the
second band (ON2-OFF2). In case nothing is to be changed
press the D key, the fourth from the top in the model D.A. 5P
(ref. 3, fig. 17|. After having confirmed OFF2, exit form the
menu is automatic. In model D.A. 3P to exit from the function
it's necessary to scroll in a sequence the settable time bands
by means of the "UP" and "DOWN" keys.
This level visualizes in sequence when and how drink
dispensing is free.
Press "ENTER" to access the change to the single items.
FREE VEND ALWAYS
ON/OFF TIME
This function allows the setting of the vending machine
automatic start up and shutdown time within a period of one
week. Press "ENTER" to set this option.
The second line of the display shows the currently assigned
parameter. - Press "ENTER" to change it.
- A flashing cursor appears on the left.
- Use the "UP" and "DOWN" keys to vary the parameter
choice among the three available ones ("ALWAYS",
"NEVER" and "TIME RANGE").
- Press ENTER to store the choice to memory.
Confirmation automatically displays the previous level.
Use the "UP" and "DOWN" keys to move to the change
of the next item.
FREE VEND
By choosing this option ("TIME RANGE") two time intervals
are available during which drinks may be dispensed for free.
For each one of them it's necessary to enter the starting time
(ON1 - OFF1) and the ending time (ON2 - OFF2).
Press "ENTER" to access the setting of the free dispensing
periods.
ON/OFF
To set this option follow the follow the procedure described in
chapter "7.5 Changing and saving parameters".
TIME ON1
If "YES" is selected, two start up and shutdown time bands
(ON1 - OFF1, ON2 - OFF2) are required. To program days and
times follow the procedure as per the "FREE VEND - TIME
RANGE" item.
FREE VEND ON1
FREE VEND OFF1
mtwtfss 00:00
FREE VEND ON2
mtwtfss 00:00
FREE VEND OFF2
mtwtfss 00:00
The modifiable parameter is on the second line of the
display.
20
DISCOUNT
This function allows the setting of a discount on the drink
price, to be applied in the course of the week in two different
time bands. To set this option follow the procedure described
in chapter "7.5 Changing and saving parameters".
Important
the discount is settable with values varying from 10
to the lowest drink price, with 10-by-ten steps.