25
English
COUNTERS
CODE DISTRIBUT.
001007
COFFEE COUNTER
*TT:000023 PP:00023*
BEVERAGE COUNTER
*TT:000023 PP:00023*
BEVERAGE A
*TT:000010 PP:00003*
SOLUB. COUNTER
*TT:000023 PP:00023*
RESET
— ->Y< N ++
SOLUBLE 1
*TT:000010 PP:00003*
STOP
Using the programming menus
NOTE: The numbers for each message do not refer to a unit of measure (gr, ml, etc.), but rather act as
reference numbers only.
OPERATING SYSTEM PROGRAMMING
It allows you to assign an identification code to each machine. To set a
code, press ENTER. The blinking cursor appears under the first number on
the left. By using the + and - buttons, you can set the first number of the
code. Press ENTER to save the number. Proceed in a similar manner to set
the remaining five numbers.
It allows you to check the number of beverages dispensed, both in vend and
free-vend mode. Press ENTER to proceed to the individual beverage counters.
On the second line of each message, two abbreviations precede the numbers.
The first abbreviation, TT, indicates a total number count, that is, the total
number of each dispensed beverage. This number cannot be reset. The abbre-
viation PP indicates a partial number count, that is, the number of each di-
spensed beverage since the last partial counter reset for that beverage.
Using the + and - buttons, you can display the values corresponding to
the number of every individual dispensed beverage, then move to the next
message.
Using the + and - buttons, you can display the total and partial values
corresponding to the number of dispensed beverages of each of the four
soluble products, then move to the next message.
It allows you to reset all abovementioned partial counters. Press ENTER to acti-
vate the blinking cursor. By using the + and - buttons, you can select (
YESYES
YESYES
YES).
Confirm reset function by pressing ENTER, and all counters will be reset.
NOTE: Quick reset function. To reset without entering the programming mode (e.g.: for use by operators
without the password), follow this procedure:
- Depress the reset button ref. 12 (Fig. 22) for approx. 3 seconds. The machine will emit a beeping sound.
- Depress the programming access button ref. 11 (Fig. 22) for approx. 3 seconds to confirm the
reset function and stop the beeping sound. If the programming access button ref. 11 is not pressed,
the beeping sound will automatically stop after 10 seconds but the reset function will not be
performed. This procedure also automatically resets the “
STOP VALUESTOP VALUE
STOP VALUESTOP VALUE
STOP VALUE
” counters.
- This function is activated in conjunction with the activation of “
FREE VENDFREE VEND
FREE VENDFREE VEND
FREE VEND
”, as stated below in
the “
FREE/RESET BUTTONFREE/RESET BUTTON
FREE/RESET BUTTONFREE/RESET BUTTON
FREE/RESET BUTTON
” section at pg. 32.
It allows you to set the maximum number of each beverage to be dispen-
sed. When the maximum number is reached, the machine will automatical-
ly stop dispensing the corresponding beverage(stop value). The blinking red
LED corresponding to the beverage selection button indicates that the beve-
rage is not available. Press ENTER to select the stop values. Use the + and
- buttons to scroll through in sequence. The numbers on the second line
preceded by ** refer to the product quantity (coffee or soluble product)
dispensed since the last reset. Numbers preceded by LIM indicate the ma-
ximum quantity (LIMIT) that can be dispensed.