Configuration
OTHER CODES CODE DATA COMMENTS
Detect dial tone *83* - # 0 = Off
1 = On (default)
Set to off if SafeLine has problem to detect
the dial tone.
Receipt to alarm receiver
with P100 protocol
*84* - # Select which message(s) to send to the alarm
receiver at an alarm call.
0 = None (default)
1 = Start of alarm
2 = Start+end of alarm
Break on new alarm *86* - # Disconnects a call longer than 60 seconds at
new activation of the alarm button and calls
the next emergency call number.
0 = Off
1 = On (default)
Alarm button delay time *87* - - # Delay time from pressing the alarm button
until activating the alarm.
00-25 seconds. Default = 05
Outputs *88* - - # The first digit specifies the output, i.e Output 1
or Output 2.
The second digit specifies the function:
0 = Pictogram
(Output 1 - Yellow, Output 2 - Green)
1 = Activate with DTMF 8/9
(Output 1 - DTMF 8, Output 2 - DTMF 9)
2 = System failure
3 = Alarm
Example:
*88*11# - Output 1, Activate with DTMF 8
*88*23# - Output 2, Alarm
Alarm button type *89* - # 0 = Normally-open contact, N/O (Default)
1 = Normally-closed contact, N/C