Configuration
OTHER CODES CODE DATA COMMENTS
Microphone sensitivity *90* - # The sensitivity of the microphone can be
reduced in three levels.
0 = No reduction (default)
1 = 20 % Reduction
2 = 40 % Reduction
3 = 60 % Reduction
Change password *91* - - - - # Change password (default=0000).
Operator silence
disconnect
*92* - # Disconnects the call when the alarm operator
has been quiet for longer than the time set.
0 = Off (default)
1 = 30 sec
2 = 60 sec
3 = 90 sec
Simulate an alarm event *94* - # Triggers an alarm event after configuration is
terminated.
1 = Emergency call
2 = Test alarm
3 = Battery failure
4 = Microphone/Speaker failure
5 = Receipt on voice call
6 = Maintenance
7 = Main unit power failure
8 = Stuck button alarm
Reset to default settings *99* - # 1 = Factory standard
2 = Default P100 (The following codes will be set):
*21*0#, *22*0#, * 27*03#, *76*4#, *80*1#,
*84*1#, *88*1#
3 = Default CPC (The following codes will be set):
*21*3#, *22*3#, *27*03#,
*76*4#,
*80*1#,
*84*1#, *88*1#
4 = Default VOICE (The following codes will
be set):
*21*1#, *22*1#, *27*03#, *
*76*4#,
80*1#,
*84*1#, *88*1#