Auto-Ack Individual Auto acknowledgement of individually addressed,
non distress DSC messages
OFF
ON (default)
Non-Distr. Inactivity Inactivity time-out to exit non-distress functions (e.g.
in setup) without automatic time-out (OFF):
Range: OFF, 1 to 30 minutes, in 1 min. steps
Default: 15min.
Distress Inactivity Inactivity time-out for received distress DSC
automated procedures without automatic time-out:
Range: OFF, 1 to 30 minutes, in 1 min. steps
Default: OFF
Comm Inactivity Inactivity time-out of non DSC communication (VHF).
Range: 10 to 600 seconds, in 10 s steps
Default: 30sec
Non-Distr.Alarms Non-distress DSC alarms
OFF: Disabled
ON: Enabled (default)
Medical transport ON: This option is available in DSC calls of the type
Urgency.
OFF (default)
Neutral crafts ON: This option is available in DSC calls of the type
Urgency.
OFF (default)
Print DSC For printing of DSC messages on a printer connected
to the system.
ON:
OFF: (default)
DSC setting Description