8000m Series
- 45 -
Function
Code
Function Descriptions
Minimum
Unit
Factory
Setting
Modifica-
tion Type
F8 Group: Auxiliary Function Parameters
F8.00
Jog running
frequency
0.00~F0.10 0.01Hz 5.00Hz ○
F8.01
Jog running
acceleration time
0.1~3600s 0.1s
Defined
by
inverter
model
○
F8.02
Jog running
deceleration time
0.1~3600s 0.1s ○
F8.03
Acceleration time
2
0.1~3600s 0.1s ○
F8.04
Deceleration time
2
0.1~3600s 0.1s ○
F8.05
Acceleration time
3
0.1~3600s 0.1s ○
F8.06
Deceleration time
3
0.1~3600s 0.1s ○
F8.07
Acceleration time
4
0.1~3600s 0.1s ○
F8.08
Deceleration time
4
0.1~3600s 0.1s ○
F8.09 Jump frequency 1 0.00~F0.10 0.01Hz 0.00Hz ○
F8.10 Jump frequency 2 0.00~F0.10 0.01Hz 0.00Hz ○
F8.11
Jump frequency
width
0.00~F0.10 0.01Hz 0.00Hz ○
F8.12
Frequency
detection
value(FDT)
0.00~F0.10 0.01Hz 50.00Hz ○
F8.13 FDT hysteresis 0.0~100.0% 0.10% 5.00% ○
F8.14
Detecting range of
reached frequency
0.0~100.0% (Maxi. Frequency) 0.10% 0.00% ○