6.5 Inverter Setting Review
After commissioning, the device info including device basic info, running info and event info can be viewed.
Country and grid code can be viewed from initial setting.
6.6 Remote Monitoring
Connect the internet via the eSolar AIO3 module, and upload the inverter data onto the
server and customers could monitor running information of the inverter remotely via the eSolar Web Portal or
their mobile customer terminals.
For details, refer to the user manual of the communication module.
6.7 Working Modes
6.7.1 Selecting Working Modes Procedures
6.7.2 Working Modes Introduction
Self-consumption Mode: When the solar is sufficient, electricity generated by photovoltaic system will
be supplied to load first, the surplus energy will be stored in battery, then the excess electricity will be
exported to the grid. When the solar is insufficient, the battery will release electricity to supply load.
Back-up Mode: Reserved Backup SOC setting value can be adjusted, when battery SOC is less than
reserved SOC value, battery can only be charged, until SOC reaches reserved value, the battery will be
stopped charging; when SOC is larger than SOC setting value, battery will behave as Self-use mode.
Time-of-use Mode: Battery charging period and discharging period can be set , during charging period,
battery can only be charged, while in discharging period, battery can only be discharged, the rest of the
period, battery will behave as Self-use mode.