EasyManua.ls Logo

Salus 091FLRF - Span Settings Explanation

Salus 091FLRF
30 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
23
GB
Span is the temperature difference between the turn on
temperature and turn off temperature. 0.5ºC or 1ºC of span can be
selected and the effect is summarized in the following table:
Span Heating System Cooling System
0.5°C
On
when.....
Tr<=Ts-0.2 Tr>=Ts+0.2
Off
when.....
Tr>=Ts+0.2 Tr<=Ts-0.2
1°C
On
when.....
Tr<=Ts-0.4 Tr>=Ts+0.4
Off
when.....
Tr>=Ts+0.4 Tr<=Ts-0.4
Ts: Set temperature
Tr: Room temperature
For example, if you set the temperature to 20°C and span = 1, the
heater will operate when the room temperature drops to 19.6°C and
turns off when the temperature rises to 20.4°C