582156110-EN-indC-Pump-20F50 pH.docx 20/11/2020
19
4 Environment
The equipment is installed on a horizontal, stable and flat floor (e.g.
concrete slab).
Non-movable equipment must be fixed to the ground by suitable
mounting devices (spit, screws, bolts, etc.) to ensure its stability during
use.
To avoid risks due to static electricity, the equipment and its
components must be grounded.
For pumping equipment (pumps, lifts, chassis, etc.), a 2.5
mm section wire is attached to the equipment. Use this
wire to connect the equipment to the general
ground. In the case of severe environments
(insufficient mechanical protection of the earthing wire,
vibrations, moving equipment, etc.) where damage to
the earthing function is likely, the user must replace the
2, 5 mm wire supplied, by a device more suited to its
environment (larger wire section, earth braid, fixing by
eye lug,).
Have the ground continuity checked by a qualified
electrician. If ground continuity is not assured, check
terminal, wire and grounding point. Never operate the
equipment without first resolving this problem.
The gun must be "grounded" through the air hose or
fluid hose. When spraying from a gun, the fluid hose
must be conductive.
The equipments to be painted must also be grounded
by means of clamps fitted with cables or, if suspended,
by means of hooks which must be kept clean
permanently.
Note: all objects in the work area must also be
grounded.
Do not store more flammable materials than necessary
inside the work area.
These materials must be stored in approved, grounded
containers.
Use only grounded metal pails for flushing solvents.
Cardboard and papers are to be banned. They are very
bad conductors, even insulators.