11 Use of the equipment
11.1 User settings
Pump
Before starting up, connect the pump to the ground.
Attention
The pump is a FLOWMAX® one :
Fluid section filling pressure : maximum 2 bar / 29 psi,
WARNING : Do not create overpressure,
Never operate the pump when an isolating gate on
the supply circuit (upstream from the fluid section) is
shut because it will damage the bellows,
Do not install a fluid regulator on the supply circuit or
any device that could perform as a non-return valve.
Motor
A relief-valve (setting : 6.5 bar / 94 psi) is fitted on the pump air motor
thus protecting this one from an overpressure which could damage it.
11.2 Safety in production
Guards (motor cover, coupling guard,
housings, ...) are set up for safe use of the equipment.
The manufacturer cannot be held responsible in case of
bodily injury as well as breakdowns and / or damage of
the material resulting from the destruction, hiding or total
or partial removal of guards.