EB 8097 EN 3-5
Design and principle of operation
3.3 Additionalttings
Strainers
SAMSON recommends installing a SAM-
SON strainer upstream of the valve. It pre-
vents solid particles in the process medium
from damaging the valve.
Bypass and shut-off valves
SAMSON recommends installing a shut-off
valve both upstream of the strainer and
downstream of the valve and installing a by-
pass line. The bypass ensures that the plant
does not need to be shut down for service
and repair work on the valve.
Safety guard
For operating conditions that require in-
creased safety (e.g. in cases where the valve
is freely accessible to untrained staff), a safe-
ty guard must be installed to rule out a crush
hazard arising from moving parts (actuator
and plug stem). Plant operators are responsi-
ble for deciding whether a guard is to be
used. The decision is based on the risk posed
by the plant and its operating conditions.
3.4 Valve accessories
Information Sheet uT8350
Any devices mounted on 3-A-compliant
valves must also comply with 3-A regula-
tions.
3.5 Technical data
The nameplates on the valve and actuator
provide information on the control valve ver-
sion. See the 'Markings on the device' chap-
ter.
More information is available in the follow-
ing data sheets:
uT8097 for Type3347 Hygienic Angle
Valve with Type3271/3277 or Type3379
uT8097-1 for Type3347/3372 Pneumatic
Control Valve
Noise emissions
SAMSON is unable to make general state-
ments about noise emissions. The noise emis-
sions depend on the valve version, plant fa-
cilities and process medium.
Note
Note