EB 8313-3 EN 3-9
Design and principle of operation
Table 3-4: Technical data
Actuator area 120cm² 350cm²
Bench range in bar
0.4 to
1.4
1.4 to 2.3
2.1 to
3.3
1.5 to
2.1
2.1 to
2.7
1.5 to
2.7
2.2 to
3.8
Fail-safe action Stem
retracts
(FE)
Stem
retracts
(FE)
Stem
extends
(FA)
Stem
extends
(FA)
Stem
retracts
(FE)
Stem
extends
(FA)
Stem
retracts
(FE)
Stem
extends
(FA)
Travel 15mm 30mm
Supply pressure Max. 6bar
1)
Ambient tempera-
ture range
–35 to +90 °C
2)
–35 to +90 °C
2)
Dimensions Refer to Fig.3-7 Refer to Fig.3-8
Weight, approx. 3.3kg 15kg
Material
Actuator housing Aluminum, powder paint coated 1.0332
Diaphragm NBR NBR
Actuator stem 1.4305 1.4401/1.4404
Electropneumatic positioner
Type3725 Refer to Data Sheet uT8394 and Mounting and Operating Instructions
uEB8394
Electric limit switch
Type4744-2
One electric limit contact · 15mm travel range
uT8367 and u
EB8367
–
1)
See the 'Operation' section for restrictions in on/off service.
2)