EasyManua.ls Logo

Samson 4763 - Emergency Actions

Samson 4763
78 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EB 8359-2 EN 9-1
Malfunction
8 Malfunction
Risk of fatal injury due to the ignition of an
explosive atmosphere.
Î Installation, operation or maintenance of
the positioner must only be performed by
personnel who has undergone special
training or instructions or who is autho-
rized to work on explosion-protected de-
vices in hazardous areas.
Crush hazard arising from moving parts on
the valve.
Î Do not touch any moving valve parts
while the control valve is in operation.
Î Before performing any mounting or in-
stallation work on the positioner, put the
control valve out of operation by discon-
necting and locking the supply air and
control signal.
Î Do not impede the movement of the actu-
ator and plug stem by inserting objects
into the yoke.
8.1 Troubleshooting
Î See Table 8-1
Contact SAMSON's After-sales Service for
malfunctions not listed in the table.
8.2 Emergency action
Upon failure of the air supply or electric sig-
nal, the positioner vents the actuator, causing
the valve to move to the fail-safe position de-
termined by the actuator.
Emergency action in the event of valve or ac-
tuator failure is described in the associated
valve and actuator documentation.
Î Plant operators are responsible for emer-
gency action to be taken in the plant.