Piping Diagram
Samsung Electronics 261
Operation modes
▪ Purpose
Classify operation modes to provide optimum performance to satisfy different user preferences.
▪ Concept
-
These modes are used to maintain system performance.
▪ Control specifications in detail
-
- Available modes: Auto / Cooling / Heating / Dry / Fan / Defrost / Oil Recovery / Turbo
3 K < |Ts - Ti|
Mid High
Relay fan Other fans
Mode Fan speed EEV Set temp Remark
Auto
Fixed
Auto1)
Control 18-30℃ User selection
Cooling
User input
Control 18-30℃
User selection
Min.16℃ for RAC
Dry
Fixed
Auto2)
Control 18-30℃
User selection
Min.16℃ for RAC
Heating
User input
Control 16-30℃ User selection
Turbo
Fixed
High, Turbo
Control Unable
Operating for 30mins
then return to previous
Fan
User input
Fixed
(Close)
- User selection
Defrost Stop
Fixed
(Open)
- System
Oil recovery
User input
Control - System
7-3 Functions (cont.)
7-3-2-6 Indoor unit control