Samsung Electronics 60
Disassembly and Reassembly
3-2-13 Removal Instructions for the DC Reactors and EMI PBA
3-2 Disassembly and Reassembly (cont.)
No. Work Procedure Remark
13
- Unfasten the DC Reactor wire screws, and then lift and
separate the Reactors.
(applicable to both Reactors #1 and #2).
DC_Reactor #1
DC_Reactor #2
- Remove the connectors inside the EMI PBA, and then unfasten
the four screws fixing the case on the PBA.
EMI PBA #2
EMI PBA #1