Key Options
Samsung Electronics 291
8-4 How to check the view mode using a tact switch (cont.)
AM080/100/120/140/160/180/200/220/240/260AXVAGH, AM100/120/140/160/180AXVDGH
K1 control KEY operation Display on segment
Press and hold 1 time Auto trial operation "K"K"BLANK"BLANK"
K1
(Number of press)
KEY operation Display on segment
1 time Refrigerant charging in Heating mode "K"1"BLANK"BLANK"
2 times Trial operation in Heating mode "K"2"BLANK"BLANK"
3 times Pump out in Heating mode (Outdoor unit address 1) "K"3"BLANK"1"
4 times Pump out in Heating mode (Outdoor unit address 2) "K"3"BLANK"2"
5 times Pump out in Heating mode (Outdoor unit address 3) "K"3"BLANK"3"
6 times Pump out in Heating mode (Outdoor unit address 4) "K"3"BLANK"4"
7 times Vaccuming (Outdoor unit address 1) "K"4"BLANK"1"
8 times Vaccuming (Outdoor unit address 2) "K"4"BLANK"2"
9 times Vaccuming (Outdoor unit address 3) "K"4"BLANK " "3"
10 times Vaccuming (Outdoor unit address 4) "K"4"BLANK"4"
11 times Vaccuming (All outdoor units) "K"4"BLANK"A"
12 times Inverter Fault Detection(Comp#1) "K"5"I"1"
13 times Inverter Fault Detection(Comp#2) "K"5"I"1"
14 times Inverter Fault Detection(Fan#1) "K"5"F"1"
15 times Inverter Fault Detection(Fan#2) "K"5"F"2"
16 times End Key operation -
-
door unit, be sure to stop the compressor and then remove the connected pipes.
an explosion or product malfunction.
WARNING