Disassembly and Reassembly
Samsung Electronics
Service Manual
5-23
1. Before you remove the Shield Main Lower(with Main
PBA), you should remove:
- LIU Unit (Refer to 5.15)
2. Unplug the all connectors from the Main PBA.
3. Remove the five screws securing the Shield Main
Lower(with Main PBA) and remove it.
4. If necnsary, remove the four screws securing the Main
PBA and remove it, as shown below.
5. The connectors are located, as shown below.