Loading...
LED R&D Lab(VD)
32
4. Frame Installation
Height differenc e
greater than 0.5 mm
Fig.7 Checking height difference Fig.8 Adjusting height difference
Fig.6 Installing cabinets
Height differenc e
smaller than 0.0 mm
Height
dif f erence
Height
dif f erence
Cabinet
After installing the Bracket Center, install the lowest row cabinets. (See Fig.6.)
After installing the cabinets, push the LED modules toward the middle and check the height
difference between the cabinets on both ends and the LED modules.
(See Fig.7.)
Roughly adjust the height difference between the left and right sides, and make fine adjustment as
shown below.
(See Fig.8.) Very important
• If the height difference is greater than 0.5 mm, move the frame outwardly.
If the height difference is smaller than 0.0 mm, move the frame inwardly.
Adjust height difference each time an additional cabinet is installed. (Use the Bracket Center for each model in the appropriate
column.)
It is not necessary to adjust a height difference in the 0.0 to 0.5 mm range.
※ Failure to comply with the above may result in poor cabinet installation, difficulty in maintenance due to difficulty in removing
the module, or module breakaway due to excessive assembly.
After adjustment is completed, install the Bracket Middle. (See step for details on how to install.)
Lastly, install the Bracket Side.
Bracket Center’s usable section,
VG-LFR53FWL: Every 3 rows
VG-LFR52SWL: Every 3 rows
VG-LFR84FWL: Every 4 rows