Item SCB-9050 SCB-9051
Detector
320(H)x240(H) Uncooled VOX Microbolometer
Sensor Pitch
23.5μm × 23.5μm
Measured wavelength range
8 ~ 14um
Video ratio (Sensor)
NTSC : 30 fps / PAL : 25 fps
Video output
CVBS : 1.0VP-P, 75Ω composite
Lens
F1.4, f=14mm F1.4, f=50mm
Focus Range
0.5m ~ ∞
(Factory default : 3m~∞,Pan Focus )
27m ~ ∞, Pan Focus
Viewing angle(H x V)
30˚ x 22.8˚ 9.2˚x 6.9˚
IFOV (Instantaneous field of view)
1.68mrad 0.47 mrad
Digital zoom
2x ~ 4x
Noise reduction function
3D-DNR (4step : Low/Midium/High/Off)
Polarity function
BW(Black & White) / WB(White & Black)
Detecting temperature
Auto / Manual(2step)
Low(-40~150), High(0~540)
Communications specifications
RS-485
Protocol
Samsung Techwin, Pelco-D
Dustproof/waterproof
protection rating
IP66
Operating temperature
-30
~ 55
Storage temperature
-40
~ 70
Input voltage
24V AC, 50/60Hz
Electricity consumption
10.5W (Operating Heater 22W)
Outer diameter size
104(W)×123(H)×352(D) mm 104(W)×123(H)×367(D) mm
Weight (Camera)
2.2Kg
Image Processing
AGC & DDE
NETD
80mK
Low range : 80mK,
High range : 300mK
* Although the infrared sensor has been built using high-precision technology, please understand that there
may be times when pixels may be lost, or remain stuck/flashing. Also, be aware that continuously monitoring
ahightemperatureobjectbeyondacertainperiodoftimemayproduceanafterimage.
* In cases where the product installation site experiences a sudden change in temperature (dropping by 15°C
ormore),thecamera’sfocuswillbecomeblurredwithregardstosubjectslocatedwithinthreemeters.
Specifications
MAIN SETUP
1. BRIGHTNESS AUTO
2. CONTRAST MANUAL
3. RANGE AUTO
4. NUC
5. NUC MOOE INTERVAL
6. IMAGE ADJ
7. SPECIAL
8. SAVE
9. EXIT
PresstheSETbuttonwhilethecursorisalignedwith“9.EXIT”toclosetheMAINSETUPmenu.
AfterswitchingBRIGHTNESSand/orCONTRASTtoMANUALandsavingyourchanges,images
maynotbedisplayedthenexttimeyourestartthedevice.Torenderimagesinsuchacase,set
BRIGHTNESSand/orCONTRASTto“AUTO”orreadjusttheMANUALsetting.
If you save after changing the RS485 communications CAMERA ID, the ID will then be set/stored.
If the CAMERA ID was set incorrectly, exit without saving.
EXIT (Close Menu)
Do not disengage the power while settings are being saved.