EasyManua.ls Logo

Samsung SCB-9050 - Powering and Initial Startup; Calibration and Monitor Connection

Samsung SCB-9050
19 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Thermal Night Vision Camera User Guide
12
Thermal Night Vision Camera User Guide
13
Inputting Power
Startup
Connect the video output terminal on the rear of this product to the monitor.
Connecting the Monitor
IR camera
Intermediate video receiver
End equipment
* Deviations may occur depending on the type of power cable shown in the chart above, and on the
wiring manufacturer.
When the resistance value of copper wire is at [20°C(68°F)]
Copper wire size (AWG)
#24(0.22
2
) #22(0.33
2
) #20(0.52
2
) #18(0.83
2
)
Resistance (Ω/m)
0.078 0.050 0.030 0.018
Voltage Drop (V/m)
0.028 0.018 0.011 0.006
•Thisdeviceisnotfittedwithapowerswitch.Thedevice
must be provided with power to turn it
•Aftercheckingthelabelonthecableontherightsideof
the camera, connect the output cable of the provided
adapter.
•Refertotheowner’smanualforeachdevice.Connectionmethodsemployedmaydiffer
depending on the monitors and peripheral devices used.
•Beforeconnectingdevices,ensuretheirpoweristurnedoff.
•Adjustthe75Ω/Hi-Zconversionswitchforeachdevicebasedonthefollowing
illustration.Select“Hi-Z”forintermediatevideoreceiversand“75Ω”forendequipment.
Calibration (NUC MODE)
Monitor/Communications Connection
Installing the Camera
1. Remove the lens cap.
2. Engage the power. (Use the adapter provided with this product.)
3.TheratedinputvoltageforthisproductisAC24V,50/60Hz.
1.TheSTARTscreenwillappearafterthepowerhasbeenturnedon.
2. After completion of initialization, thermal images will be displayed. (approx. ten seconds
after engaging the power)
Thisdevicewillperformacalibrationnecessaryforimaging(NUC)aftertheinternalshutter
closes.
During NUC, the screen will freeze momentarily. Please note that this is not a malfunction.
Thesensorwillnotoperateproperlyimmediatelyafterthepoweristurnedon,orwhenswitching
between HIGH and LOW ranges. As a result, thermal images will not display consistently for several
seconds.Menucontrolscanbeusedtosavevaluestobeappliedatsubsequentstart-upofthe
SCB-9050/9051. (If values are not saved, then the last saved settings will be applied.)
A 22-18 gauge power wire is recommended for this camera.
Voltage reinforcement will occur based on the length of the power wire. If the adapter
output wire is too long, camera performance may suffer.
Notes
IR camera Monitor