Code NVM Description Meaning Component Default
Maximum /
Minimum
08-100 Pick up roller Life Page
Counter
[Read Only] Engine 0 Read Only
08-110 Forward roller Life Page
Counter
[Read Only] Engine 0 Read Only
08-120 Retard roller Life Page
Counter
[Read Only] Engine 0 Read Only
08-130 Tray2 Pick-Up Roller
Life Page Counter
[Read Only] Engine 0 Read Only
08-140 Tray3 Pick-Up Roller
Life Page Counter
[Read Only] Engine 0 Read Only
08-150 Tray4 Pick-Up Roller
Life Page Counter
[Read Only] Engine 0 Read Only
08-160 Bypass Rubber Pad Life
Page Counter
[Read Only] Engine 0 Read Only
3) Developer
Code NVM Description Meaning Component Default
Maximum /
Minimum
09-100 LD Light Level 600dpi Laser Light Level,Value in PWM Engine 250 50~800 [250]
09-110 MHV Control Bias
Control
Main Charge Bias Control
Basic of Value(HVPS Setting is Value),Value in
PWM
Engine 710 600~850 [710]
09-120 THV Control Bias Control Transfer Bias Control
Basic of Value(HVPS Setting is Value),Value in
PWM
Engine 310 270~600 [310]
09-130 Deve Bias Control DEVE Bias Control
Basic of Value(HVPS Setting is Value), Value in
PWM Standard Voltage : -500V(PWM 522)
Engine 512 400~650 [512]
09-140 Detach Bias Control Detach Bias Control
Basic of Value(HVPS Setting is Value), Value in
PWM Standard Voltage : -1800V
Engine 508 200~730 [508]
09-200 Drum Life Page Counter Display of drum pages Count. Engine 0 Read Only
09-210 Toner Cartridge Life
Page Counter
Display of toner cartridge pages Count. Engine 0 Read Only
09-230 Transfer Roller Life Page
Counter
Display value of Pages Count. Engine 0 Read Only
09-240 Imaging Unit PWM Value of Imaging Unit PWM Engine 180 0 ~255 [180]