EasyManua.ls Logo

Samsung SPD-400 - Alarm Input Configuration

Samsung SPD-400
78 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
English _41
SETUP SCREEN
Alarm input
You can set the alarm input type, duration and action type of the Network Video Decoder’s
alarm input port.
1. From the Setup menu, select the
<Event ( )> tab.
2. Click <Alarm input>.
3. Select the input device type.
Type
- Normal open : It is normally open,
but if it is closed, an alarm will be
triggered.
- Normal close : It is normally closed,
but if it is open, an alarm will be
triggered.
4. Specify the <Activation time>.
Always : Always check if an alarm occurs. It activates in operated mode when the
alarm occurs.
Only scheduled time : Check if an alarm occurs at a specified day of the week for
a specified time period. It activates in operated mode when the alarm occurs.
5. Set the alarm’s output dwell time when an alarm occurs.
Alarm output : Specify the alarm output time in the alarm input setup.
If the alarm out duration is set to <Always>, the alarm continues to function until the alarm
acknowledge button is pressed, as expressed in Audio & Video page.
Test : Conducts a test alarm for the connected alarm out device.
6. When done, click [Apply ( )].