Polarization Control Unit PCU-110
5-27
Response ***.***.***.*** (*** is integer from 0 to 255)
Example :SYST:COMM:ETH:SMAS?
255.255.255.0
:SYSTem:COMMunicate:ETHernet:DGATeway
Syntax :SYSTem:COMMunicate:ETHernet:DGATeway<wsp><value>
Description Sets default gateway when DHCP is disabled.
Parameter ***.***.***.*** (*** is integer from 0 to 255)
Response None
Example :SYST:COMM:ETH:DGAT 192.168.0.254
:SYSTem:COMMunicate:ETHernet:DGATeway?
Syntax :SYSTem:COMMunicate:ETHernet:DGATeway?
Description Reads out default gateway
Parameter None
Response ***.***.***.*** (*** is integer from 0 to 255)
Example :SYST:COMM:ETH:DGAT?
192.168.0.254
:SYSTem:COMMunicate:ETHernet:PORT
Syntax :SYSTem:COMMunicate:ETHernet:PORT<wsp><value>
Description Sets port number
Parameter Integer from 0 to 65535
Response None
Example :SYST:COMM:ETH:PORT 64000
:SYSTem:COMMunicate:ETHernet:PORT?
Syntax :SYSTem:COMMunicate:ETHernet:PORT?
Description Reads out port number
Parameter None
Response Integer from 0 to 65535
Example :SYST:COMM:ETH:PORT?
64000