EasyManua.ls Logo

Sanyo MIR-554 - Control Panel Functions Overview; Standby Operation Mode

Sanyo MIR-554
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16
FUNCTIONS THROUGH CONTROL PANEL
The following functions are available through control panel:
Setting of standby operation: To set a running condition at the start-up or completion of
programmed running. (refer to page 16
Programming and edit: To set a new program (page 21), or to edit (page 27), or delete (page 42) an
user program.
Programmed running: To start (page 28), skip (page 31) or stop (page 32) a programmed running.
Setting of defrost: To set the automatic defrost (page 33) and to start the manual defrost. (page 34)
Setting of log cycle and sending to PC: To set a log cycle of running data and to send a running
log to PC. (page 37)
Setting of date and time: To set the date and time shown on the top screen. (page 38)
Setting of alarm: To set temperature alarm (page 39) and a high limit (or low limit) temperature alarm.
(page 20)
Setting for optional component: To set when an optional component is installed. (page 39)
Setting of low humidity mode: To set the running for low humidity. (page 39)
Default setting: To set the default for LCD panel and communication (DAQ) speed etc. (page 41)
STANDBY OPERATION (MENU/Std-by)
This product automatically operates with standby operation setting.
1. With the top screen displayed, press the menu button (MENU) to show the menu window. Select
“Std-by” and press the enter key (ENTER).
2. Stand-by Setting screen is displayed. Set each parameter.
3. Press the menu button (MENU) at the completion of parameter setting. The menu window is shown.
Select “OK” and press the enter key (ENTER). The parameter is memorized.
The settable range of each parameter:
Temperature-1060
o
C
The settable range and screen display is -10+50
o
C when the optional inner door (MIR-55ID) is installed.
S t a n d - by S e t t i ng
T e m p e r a t u r e
2 5 . 0
o
C (-10.0
o
C - + 6 0 . 0
o
C )
L i g h t S t e p 0LS
(0.OFF 1.ON)
K e y L ock 0 ( 0. UnLock 1. Lo c k )
H i g h L i m i t 6 5
o
C
L o w L i m i t - 1 5
o
C
ME N U
O K
+
-
C a n c e l
S t a n d-b y Top Screen
T e m p 2 5 . 0
o
C
Alarm N
ormal
D
oor
Cl o s e d
L
ight
OFF
2 0 1 0 / 0 1 / 0 1 1 2 : 0 0 : 0 0
25.0℃
M E N U
Run
S t d - b y
Edi t
Too l s
M. D e f

Related product manuals