PROGRAMMING (MENU/Edit)
5. Highlight the numerical value of each time section (Time) by shift key, and input as below by character
input key.
CAUTION
The time setting value depends on each mode, clock mode and timer mode. In the case of clock mode,
the setting range is between 00:00 and 23:59. If the setting is larger than 24:00, the step of immediately
before is repeated limitlessly. Set the step with timer order. In the case of timer mode, setting range is
between 00:01 and 99:59. The setting of “99:99” causes limitless repeat.
6. Shift a cursor downward by the downward shift key. Set the temperature as follows. The setting
range is between -10.0
o
C and +60.0
o
C.
CAUTION
The settable range of chamber temperature is between -10 and +60
.
The lighting is available only with temperature range between +2 and +50
o
C when the optional light
add-on kit (MIR-L15) is installed. In the case of temperature out of range, the lighting is not usable.
When light add-on kit (sold separately) is installed, except when the set value of temperature is between
+2 and +50
o
C, the lighting is turned off.
In this case, temperature fluctuation may exceed
±
1.5
o
C or it may take longer time to pull down the
chamber temperature.
The temperature control range is -10+50
o
C when the optional inner door (MIR-55ID) is installed.
The temperature is limited to 50
o
C when the saved program includes temperature setting over 50
o
C. In
this case, the temperature setting over 50
o
C is indicated by blinking.
CAUTION
The unit continues to run with a step just before the step having time setting of over 24:00 when a
program is run in clock mode.
10St p 31Cyc
Time 6: 00 9: 00 11: 00 13: 00 15: 00 17: 00
Temp 12. 0 15.0 20.0 25.0 20.0 18.0
During temperature setting, “
o
C” is displayed at upper left.
Ti me 19: 00 21: 00 22: 00 23: 00
Temp 15. 0 15. 0 12. 0 10. 0
o
C
T i m e 1 9: 0 0 2 1 : 0 0 2 2 : 0 0 2 3 : 0 0
T e m p 4.0 4.0 4 . 0 4 . 0
1 0 S t p 3 1
C
y c
o
C
T i m e
6 : 0 0 9 : 0 0 1 1 : 0 0 1 3 : 0 0 1 5 : 0 0 1 7 : 0 0
T e m p 3 7 . 0 4 . 0 4 . 0 4 . 0 4 . 0 4 . 0
M E N U
S a v e
+ / -
C a n c e l
When adding the “-“ to the set value of temperature or erasing the “-“ from the set
value of temperature, press the menu button (MENU) to show the menu window.
Select +/- and press the enter key (ENTER).