Loading...
ALARM
TEMPERATURE
SETTING
This
unit
is
provided
with
both
high
and
low
temperature
alarms.
The
temperature
at
which
the
alarm
is
activated
may
be
changed.
The
available
set
range
for
high
temperature
alarm
is
between
+2°C
and
+14°C
and
-2°C
and
-14°C
for
low
temperature
alarm
against
the
chamber
temperature.
Display
Mode
Function
F01
High
temperature
alarm
set
See
Table
5
on
page
19
F02
Low
temperature
alarm
set
See
Table
5
on
page
19
As
an
example,
Table
3
shows
the
procedure
to
set
the
high
temperature
alarm
so
that
the
alarm
can
activate
when
the
chamber
temperature
is
3°C
higher
than
the
set
temperature.
Table
4
shows
the
procedure
to
set
the
low
temperature
alarm
so
that
the
alarm
can
activate
when
the
chamber
temperature
is
3°C
lower
than
the
set
temperature.
Table
3
Procedure
for
setting
high
temperature
alarm
Description
of
operation
Press
numerical
value
shift
key
for
2
_
5
seconds.
_
^
Press
numerical
value
shift
key
and
_
s
croll
the
figure
to
1.
_
Press
set
key.
4
Set
the
temperature
to
003
with
the
5
digit
shift
key
and
numerical
value
shift
key.
6
Press
set
key.
Key
operated
_
Indication
after
operation
The
current
chamber
temperature
is
_
d
isplayed.
_
^
The
first
digit
is
flashed.
t
W
hen
pressed,
the
figure
of
settable
_
d
igit
increases.
_
The
first
digit
is
flashed.
oh
I
Pressing
the
key
shifts
the
digit
which
can
be
set.
_
t
W
hen
pressed,
the
figure
of
settable
_
d
igit
increases.
____
Alarm
temperature
is
memorized
and
SET
the
current
chamber
temperature
is
displayed.
Table
4
Procedure
for
setting
low
temperature
alarm
Description
of
operation
^
Press
numerical
value
shift
key
for
5
seconds.
_
3
Press
numerical
value
shift
key
and
scroll
the
figure
to
2.
_
4
Press
set
key.
Set
the
temperature
to
-03
with
the
5
digit
shift
key
and
numerical
value
shift
key.
6
Press
set
key.
Key
operated
_
Indication
after
operation
The
current
chamber
temperature
is
displayed.
_
The
first
digit
is
flashed.
When
pressed,
the
figure
of
settable
digit
increases.
_
The
first
digit
is
flashed.
Pressing
the
key
shifts
the
digit
which
can
be
set.
_
When
pressed,
the
figure
of
settable
digit
increases.
_
Alarm
temperature
is
memorized
and
the
current
chamber
temperature
is
displayed.
17