Sanyo MPR-721 - SETTING OF DELAY OF DOOR ALARM

Sanyo MPR-721
39 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SETTING
OF
DELAY
OF
DOOR
ALARM
The
door
check
indicator
is
light
when
the
door
is
opened,
and
the
alarm
buzzer
sounds
with
some
delay
to
notice
the
door
opening.
The
delay
time
(between
lighting
of
the
door
check
indicator
and
activation
of
the
alarm
buzzer)
can
be
changed.
Set
an
appropriate
delay
time
according
to
the
condition
of
use
to
prevent
the
rise
of
chamber
temperature
resulting
from
inadequate
door
close.
Setting
range
of
delay
time:
1
and
15
minutes
Initial
setting
(factory
setting):
2
minutes
Table
5
Procedure
for
setting
of
delay
of
door
alarm
(Change
the
delay
time
to
3
min.
from
2
min
)
___
Description
of
operation
Key
operated
Indication
after
operation
1
The
current
chamber
temperature
is
displayed.
4
2
Press
up
arrow
key
for
5
seconds.
1
F00
is
displayed
and
the
first
digit
blinks.
F00
'IV
3
Press
up
arrow
key
4
times.
1
The
display
is
changed
to
F04
from
F00.
F0H
4
Press
set
key.
SET
The
current
setting
(002)
is
displayed
and
the
first
digit
blinks.
0133
5
Press
up
arrow
key
and
scroll
the
figure
to
3.
i
The
display
is
changed
to
003
from
002.
\l/
003
iv
6
Press
set
key.
SET
Delay
time
is
memorized
and
the
current
chamber
temperature
is
displayed.
4
Note:
The
setting
mode
returns
to
the
temperature
display
mode
automatically
when
90
seconds
has
passed
without
any
key
operation
(auto-return
function).
In
this
case,
the
setting
is
not
accepted.