-27-
Electrical Adjustments
1. Receive the 16-step grey scale computer signal.
2. Set to COMPUTER mode.
3. Enter the service mode.
[R-SIGNAL CENTER ADJUSTMENT]
4. Connect a digital voltmeter to test point TP25R1 (+)
and chassis ground (-).
5. Select group no. 3, item no. 0 and change data
value to adjust the voltage to be 7.30 ±0.05V.
[G-SIGNAL CENTER ADJUSTMENT]
6. Connect a digital voltmeter to test point TP25G1 (+)
and chassis ground (-).
7. Select group no.
3, item no. 1 and change data
value to adjust the voltage to be 7.30 ±0.05V.
[B-SIGNAL CENTER ADJUSTMENT]
8. Connect a digital voltmeter to test point TP25B1 (+)
and chassis ground (-).
9. Select group no. 3, item no. 2 and change data
value to adjust the voltage to be 7.30 ±0.05V.
1. Receive the 16-step grey scale computer signal.
2. Set to COMPUTER mode.
3. Connect an oscilloscope to test point TP3551 (+)
and chassis ground (-).
4. Enter the service mode, select group no. 3, item no.
7 and change data value to adjust amplitude a to
be 5.5 ±0.1V.
(a)
Signal Center adjustment
NRS adjustment
1. Receive the 16-step grey scale computer signal.
2. Set to COMPUTER mode.
3. Enter the service mode.
[R-BLACK ADJUSTMENT]
4. Connect an oscilloscope to test point TP25R1 (+)
and chassis ground (-).
5. Select group no. 3, item no. 3 and change data
value to adjust amplitude a to be 10.0 ±0.1V.
[R-BLACK ADJUSTMENT-]
6. Connect an oscilloscope to test point TP25G1 (+)
and chassis ground (-).
7. Select group no. 3, item no. 4 and change data
value to adjust amplitude a to be 10.0 ±0.1V.
[R-BLACK ADJUSTMENT-]
8. Connect an oscilloscope to test point TP25B1 (+)
and chassis ground (-).
9. Select group no. 3, item no. 5 and change data
value to adjust amplitude a to be 10.0 ±0.1V.
(a)
black level
black level
Black Level adjustment