-28-
Electrical Adjustments
1. Receive the 16-step gray scale computer signal.
2. Set to COMPUTER mode.
3. Enter the service mode.
[R-GAIN ADJUSTMENT]
4. Connect an oscilloscope to test point TP25R1 (+)
and chassis ground (-).
5. Select group no. 2, item no. 3 and change data
value to adjust waveform a to be minimum ampli-
tude.
[G-GAIN ADJUSTMENT]
6. Connect an oscilloscope to test point TP25G1 (+)
and chassis ground (-).
7. Select group no. 2, item no. 4 and change data
value to adjust waveform a to be minimum ampli-
tude.
[B-GAIN ADJUSTMENT]
8. Connect an oscilloscope to test point TP25B1 (+)
and chassis ground (-).
9. Select group no. 2, item no. 5 and change data
value to adjust waveform a to be minimum ampli-
tude.
White Level
(a)
PC Gain adjustment
1. Receive the 16-step gray scale computer signal.
2. Set to COMPUTER mode.
3. Enter the service mode.
[R-OFFSET ADJUSTMENT]
4. Connect an oscilloscope to test point TP25R1 (+)
and chassis ground (-).
5. Select group no. 3, item no. 11 and change data
value to adjust the waveform a (black portion ) to
be maximum amplitude.
[G-OFFSET ADJUSTMENT]
6. Connect an oscilloscope to test point TP25G1 (+)
and chassis ground (-).
7. Select group no. 3, item no. 12 and change data
value to adjust the waveform a (black portion ) to
be maximum amplitude.
[B-OFFSET ADJUSTMENT]
8. Connect an oscilloscope to test point TP25B1 (+)
and chassis ground (-).
9. Select group no. 3, item no. 13 and change data
value to adjust the waveform a (black portion ) to
be maximum amplitude.
Black Level
(a)
PC Offset adjustment