-70-
Electrical Adjustment
Group/Item Item Name Function Initial Range Note
6 Temp B Warning (Normal) Temp B (Lamp) to judge the Failure at Normal Mode 67 67 67 67 30-100
L1
160°
200°
20°
340°
(-20°)
(-160°)
L2
Normal Ceiling
Off L1 L2
Off Normal Up Down
On Ceiling Up Down
Slant
Ceiling
Definition of Slant
Off -20° ~ 20°
L1 20° ~ 160°
L2 -20° ~ -160°
7 Temp C Warning (Normal) Temp C (Panel) to judge the Failure at Normal Mode 52 52 52 52 30-100
8 Temp B-A Warning (Normal) Temp B-A (Clog) to judge the Failure at Normal Mode 100 100 100 100 0-100
9 Temp C-A Warning (Normal) Temp C-A (Clog) to judge the Failure at Normal Mode 100 100 100 100 0-100
10 Temp A Warning (Eco) Temp A (Room) to judge the Failure at Eco Mode 47 47 47 47 30-100
11 Temp B Warning (Eco) Temp B (Lamp) to judge the Failure at Eco Mode 67 67 67 67 30-100
12 Temp C Warning (Eco) Temp C (Panel) to judge the Failure at Eco Mode 51 51 51 51 30-100
13 Temp B-A Warning (Eco) Temp B-A (Clog) to judge the Failure at Eco Mode 100 100 100 100 0-100
14 Temp C-A Warning (Eco) Temp C-A (Clog) to judge the Failure at Eco Mode 100 100 100 100 0-100
15 Temp A Warning Offset (Temp)
Offset of Temp of Temp Error (Temp)
Offset Error Temp under the following condition.
- In the standby
- Startup period of the Lamp-on
- Switching period of the Lamp Mode
10 0-100
16 Temp B Warning Offset (Temp) 11 0-100
17 Temp C Warning Offset (Temp) 13 0-100
18 Temp B-A Warning Offset (Temp) 11 0-100
19 Temp C-A Warning Offset (Temp) 13 0-100
20 Temp A Warning Offset (Time)
Offset of Temp of Temp Error (min)
Offset Error Time under the following condition.
- In the standby
- Startup period of the Lamp-on
- Switching period of the Lamp Mode
30 0-40
21 Temp B Warning Offset (Time) 15 0-40
22 Temp C Warning Offset (Time) 15 0-40
23 Temp B-A Warning Offset (Time) 15 0-40
24 Temp C-A Warning Offset (Time) 15 0-40
254 Fan Control Range Setting (Temp/Frequency) Norm Ceil Up Down
L1
160°
200°
20°
340°
(-20°)
(-160°)
L2
Normal Ceiling
Off L1 L2
Off Normal Up Down
On Ceiling Up Down
Slant
Ceiling
Definition of Slant
Off -20° ~ 20°
L1 20° ~ 160°
L2 -20° ~ -160°
0 High Fan Control Min Temp
Temp Sensor Control Start/End Temp. at High
30 30 30 30 20-100
1 High Fan Control Max Temp 39 39 39 39 20-100
2 High Fan1 Min
Fan Operation Frequency (Min/Max) Setting at High
(rpm)
2775 2775 2775 2775 0000-9990
3 High Fan1 Max 2975 2975 2975 2975 0000-9990
4 High Fan2 Min 1800 1800 1800 1800 0000-9990
5 High Fan2 Max 2555 2555 2555 2555 0000-9990
6 High Fan3 Min 4700 4700 5900 5900 0000-9990
7 High Fan3 Max 4800 4800 6100 6100 0000-9990
8 High Fan4 Min 3120 3120 3120 3120 0000-9990
9 High Fan4 Max 5865 5865 5865 5865 0000-9990
10 Normal Fan Control Min Temp
Temp Sensor Control Start/End Temp. at Normal
30 30 30 30 20-100
11 Normal Fan Control Max Temp 39 39 39 39 20-100
12 Normal Fan1 Min
Fan Operation Frequency (Min/Max) Setting at Normal
(rpm)
2495 2495 2495 2495 0000-9990
13 Normal Fan1 Max 2795 2795 2795 2795 0000-9990
14 Normal Fan2 Min 1625 1625 1625 1625 0000-9990
15 Normal Fan2 Max 2245 2245 2245 2245 0000-9990
16 Normal Fan3 Min 3650 3650 4850 4850 0000-9990
17 Normal Fan3 Max 3725 3725 5000 5000 0000-9990
18 Normal Fan4 Min 2605 2605 2605 2605 0000-9990
19 Normal Fan4 Max 5275 5275 5275 5275 0000-9990
20 Eco Fan Control Min Temp
Temp Sensor Control Start/End Temp. at Eco
30 30 30 30 20-100
21 Eco Fan Control Max Temp 39 39 39 39 20-100
22 Eco Fan1 Min
Fan Operation Frequency (Min/Max) Setting at Eco (rpm)
2210 2210 2210 2210 0000-9990
23 Eco Fan1 Max 2610 2610 2610 2610 0000-9990
24 Eco Fan2 Min 1450 1450 1450 1450 0000-9990
25 Eco Fan2 Max 1935 1935 1935 1935 0000-9990
26 Eco Fan3 Min 2600 2600 3800 3800 0000-9990
27 Eco Fan3 Max 2650 2650 3900 3900 0000-9990
28 Eco Fan4 Min 2090 2090 2090 2090 0000-9990
29 Eco Fan4 Max 4685 4685 4685 4685 0000-9990
255 Fan Start/Cooling Setting
0 Fan1 Initial Volt
Fan Start Voltage (x0.1)
55 0-255
1 Fan2 Initial Volt 65 0-255
2 Fan3 Initial Volt 35 0-255
3 Fan4 Initial Pulse Fan Start Output 700 0-4095
4
5
6
7
8 Cooling Time
Cooling Time Setting (x30)
1: 30, 3: 90, 15: 45 sec.
3 1-15
9
10 Temp Error Cooling Time
Cooling Setting at Temp Error (x30)
1: 30, 3: 90, 15: 45 sec.
3 1-15
11 OnStaart Cooling Start Threshold 38 0-100
12 After shutdown cooling 0: No, 1: Yes 1 0-1
256 Fan Lamp Voltage Setting