Electrical Adjustment
Group/Item Item Name Function Initial Range Note
0 Fan1 Min Adjust (DAC)
FAN DAC Output Adjustment
DAC and Fan Voltage Tolerance Adjust.
* Lamp Mode: Forced Eco
60 0-255 * Fan Volatge Ad.
1 Fan1 Max Adjust (DAC) 210 0-255 * Fan Volatge Ad.
2 Fan2 Min Adjust (DAC) 60 0-255 * Fan Volatge Ad.
3 Fan2 Max Adjust (DAC) 210 0-255 * Fan Volatge Ad.
4 Fan3 Min Adjust (DAC) 60 0-255 * Fan Volatge Ad.
5 Fan3 Max Adjust (DAC) 210 0-255 * Fan Volatge Ad.
6 Fan4 Min Adjust Not used 4094 0-255
7 Fan4 Max Adjust Not used 4095 0-255
251 Fan Clogging Detection Setting Normal Highland
0 Filter Warning Calibration
Clogging Detection Offset Calibration.
Executes Filter Calibration when the value is set to 1.
0 0-1 * Filter Calibration Adj.
1 Filter Warning Offset Point 0
Clogging Detection Offset Value (Freq.)
1731 1812 0000-9999
2 Filter Warning Offset Point 1 2686 2818 0000-9999
3 Filter Warning Offset Point 2 3456 3598 0000-9999
4 Filter Warning Offset Point 3 4139 4288 0000-9999
5 Filter Warning Offset Point 4 4728 4948 0000-9999
6 Filter Warning Offset Point 5 5221 5522 0000-9999
7 Filter Warning Offset Point 6 5607 5988 0000-9999
8 Filter Warning Offset Point 7 5899 6332 0000-9999
9 Not used 9999 9999 0000-9999
10 Not used 9999 9999 0000-9999
11 Not used 9999 9999 0000-9999
12 Not used 9999 9999 0000-9999
13 Filter Warning Times Clogging Detection Time (min) 3 0-10
14 Fan-Add Filter Level 1 Fan Rotation Add Value at Clog Level 1(rpm) 1000 0000-9990
15 Fan-Add Filter Level 2 Fan Rotation Add Value at Clog Level 2(rpm) 2000 0000-9990
16 Filter Warning Calibration Range
Tlerance of Calibration
(1:±5rpm 2:±10rpm 10:±50rpm)
1 0-10
17 Filter Warning Calibration Time Calibration Time(sec) 2 1-10
18 Filter Warning Calibration Error Log
Error Log at Calibration
0: No Error
100-111: Fan Adjustment Error
200-211: Out of Offset Range
255: Not Executed
255 0-255
19
Filter Warning High Land
Calibration Error Log
Error Log at Calibration in the Highland Mode
0: No Error
100-111: Fan Adjustment Error
200-211: Out of Offset Range
255: Not Executed
255 0-255
20 Filter Warning Calibration Temp Room Temp. at Calibration Executed (x0.1) 260 -
21
Filter Warning Inclination Rpm (to
26 ºC)
Add Value of Rotation when the Room Temp increase
10 degree. (Lower than 29 ºC)
60 0000-9999
22
Filter Warning Inclination Rpm (over
26 ºC)
Add Value of Rotation when the Room Temp increase
10 degree. (Higher than 29 ºC)
80 0000-9999
23 Filter Warning Add Offset Rpm Rotation Offset - -
252 Fan Option
0 Fan Max Switch
0: Normal Operation
1: Fixed Maximum(13.5V)
0 0-1
1 Safety Switch
FAN Control Switch for Safety Test
(0: Normal 1: High Min 2: High Max3: Normal Min
4: Normal Max 5: Eco Min 6: Eco Max )
0 0-6
2 Fan Manual Switch Fan Manual SW (0: Auto 1: Mamual) 0-1
3 Fan1 Manual Voltage Fan Voltage Manual Adj. Mode (x0.1) 0-255
4 Fan2 Manual Voltage * Effective only Manual Switch is 1. 0-255
5 Fan3 Manual Voltage 0-255
6 Fan4 Manual Set
PWM Duty Ratio at Manual Adj.
* Effective only Manual Switch is 1.
0-511
7 DAC Out Stability
DAC Output Update Freq. Setting
1: Every 1 sec. 2: 2 sec. 3: 3 sec. 10: 10 sec.
2 1-10
8 All Fan MaxMin Control
Forced Fan Coltrol Mode
The setting is reset when the AC cord is disconnected.
0: Normal Operation 1: High-MIN 2: High-MAX 3:
Normal-MIN 4: Normal-MAX 5: Eco1-MIN 6: Eco1-MAX
7: Eco2-MIN 8: Eco2-MAX
0 0-8
253 Fan Temp. Error Setting Memorized Norm Ceiil L1 L2
0 Temp A Warning (High) Temp A (Room) to judge the Failure at High Mode 47 47 47 47 30-100
1 Temp B Warning (High) Temp B (Lamp) to judge the Failure at High Mode 67 67 67 67 30-100
2 Temp C Warning (High) Temp C (Panel) to judge the Failure at High Mode 52 52 52 52 30-100
3 Temp B-A Warning (High) Temp B-A (Clog) to judge the Failure at High Mode 100 100 100 100 0-100
4 Temp C-A Warning (High) Temp C-A (Clog) to judge the Failure at High Mode 100 100 100 100 0-100
5 Temp A Warning (Normal) Temp A (Room) to judge the Failure at Normal Mode 47 47 47 47 30-100