Group/Item Item Name Function Initial Range Note
22 Lamp Warning Time (ECO) Lamp Warning Time at Eco Mode 1-16
23 Lamp Warning Time (HIGH) Lamp Warning Time at High Mode 1-16
30 Lamp life test enable 0:Disable 1:Enable for Test
31 Lmap On time (for life test)
32 Lamp Off time (for life test)
33 Lamp total time (for life test)
50 Lamp Replacement Display Lamp Warning Display On/Off 1: On / 0: Off 1 0-1
51 Filter Warning Display Filter Warning Display On/Off 1: On / 0: Off 1 0-1
52 Lamp Counter Reset Times Lamp Counter Reset Times 0 0-255
53 Filter Counter Reset Times Filter Counter Reset Times 0 0-255
54 Factory Default Execute Times Factory Default Execute Times 0 0-255
55 Motor Control
Motors(LensShift, Focus, Zoom)Operation Control
0: Enable / 1: Disable
0 0-1
56 MenuPosition Change (X) Offset Value of X 0 0-1024
57 MenuPosition Change (Y) Offset Value of Y 0 0-1024
58 Lamp Go Out 0 0-1
70 ADC Device Selection Analog 0: ISL51002 / 1: PW392 AFE 0 0-1
71 ADC Device Selection Component 0: ISL51002 / 1: PW392 AFE 0 0-1
80 Desitination
Language Set at factory Default
0: English 1: Japanese
0 0-1
90 Panel Life Mode 0: On / 1: Off 1 0-1
201 Option (Signals) Not used
0 FrameLock Option
Frame Lock Option
0: Normal / 1: Off
0 0-1
205 Spread Spectrum
0 Enable 0: On / 1: Off 1 0-1
1 Spread Ratio 75 0-300
2 Modulation Frequency 300 200-500
210 Lamp Contorl
0 Dimmer SW 0:Auto / 1:Manual 0 0-1
1 Manual Control 0 0-15
2 DIMMER_CTRL_LEVEL1 Y Level 1 Data for Dim: Dim Level1 7 0-255
3 DIMMER_CTRL_LEVEL2 Y Level 1 Data for Dim: Dim Level2 14 0-255
4 DIMMER_CTRL_LEVEL3 Y Level 1 Data for Dim: Dim Level3 21 0-255
5 DIMMER_CTRL_LEVEL4 Y Level 1 Data for Dim: Dim Level4 28 0-255
6 DIMMER_CTRL_LEVEL5 Y Level 1 Data for Dim: Dim Level5 35 0-255
7 DIMMER_CTRL_LEVEL6 Y Level 1 Data for Dim: Dim Level6 42 0-255
8 DIMMER_CTRL_LEVEL7 Y Level 1 Data for Dim: Dim Level7 49 0-255
9 DIMMER_CTRL_LEVEL8 Y Level 1 Data for Dim: Dim Level8 56 0-255
10 DIMMER_CTRL_LEVEL9 Y Level 1 Data for Dim: Dim Level9 63 0-255
11 DIMMER_CTRL_LEVEL10 Y Level 1 Data for Dim: Dim Level10 70 0-255
12 DIMMER_CTRL_LEVEL11 Y Level 1 Data for Dim: Dim Level11 77 0-255
13 DIMMER_CTRL_LEVEL12 Y Level 1 Data for Dim: Dim Level12 84 0-255
14 DIMMER_CTRL_LEVEL13 Y Level 1 Data for Dim: Dim Level13 91 0-255
15 DIMMER_CTRL_LEVEL14 Y Level 1 Data for Dim: Dim Level14 98 0-255
16 DIMMER_CTRL_LEVEL15 Y Level 1 Data for Dim: Dim Level15 105 0-255
17 DIMMER_AVERAGE_POINT Dimmer Avarage Point 4 1-16
18 DIMMER_AVERAGE_DATA Dimmer Avarage Data - -
19 DIMMER_LEVEL_AUTO Dimmer Level Auto - -
20 DIMMER_LEVEL_NORMAL Dimmer Level Normal 8 0-15
21 DIMMER_LEVEL_ECO Dimmer Level Eco 0 0-15
22 Lamp check enable Not used 1 0-1
23 VOLTAGE_LEVEL Lamp Voltage - -
24 DIMMER_LEVEL_HIGH Dimmer Level High 15 0-15
220 Error Logs
0 Warning_Log_1 Latest Error 0 0-32767
- | |
49 Warning_Log_50 50th Older Error 0 0-32767
50 Warning_Log Reset Resets Error Logs when the value is set to 10. 0 0-10