EasyManua.ls Logo

Sanyo PLC-XL51A - Lamp Replacement Counter and Precautions

Sanyo PLC-XL51A
146 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 60 -
Service Adjustment
Group/
Item
Item Name Function Initial Range Note
4 Sub Image Enable 1 0 - 1
0:Disable (Service Adjustment
Dsiable, Used all the Center Values
1:Enable (Service Adjustment Enable)
6 Zoom Accelerator Enable 0 0 - 1
0:Zoom Accelerator OFF,
1:Zoom Accelerator ON
No last memory
7 DZoom Reset by Keystone 0 0 - 1
0:Enable (Normal), 1:Disable (Dzoo
is not cancelled even if Keystone is
cancelled)
No last memory
8 Stability Count Count Value of V-missing 5 0 - 255
9
Sensivity for Signal Lost
(HSYNC)
Only used this value for No Signal
Judgement(Hz)
350
0 -
32757
10
Sensivity for Signal Lost
(VSYNC)
Only used this value for No Signal
Judgement(Line)
3 0 - 255
11 Keystone Filter Center Value Reference Value 16 0 - 30
Group 203 Option (Uniformity Adjust FPGA)
0 FPGA Version FPGA Version Display Read only
1 ON / OFF
Yniformity Adjustment Setting
ON/OFF
1 0 - 1 0 : OFF 1: ON
2 MODE Table No. of FPGA 0 0 - 3 0 : TBL0, 1: TBL1 2: TBL2
3 SEL
Uniformity adjustment Method
Setting
1 0 - 1
0: Output = Input x (kH+kV) /2
1: Output = Input x (kH+kV)
4 HANTEN Adrres Reverse Setting 0 0 - 3
0 : Normal 1 : R/L reverse 2: U/D
reverse 3: R/L/U/D reverse
5 Red Gain Red Gain Setting 128/77/102/95/111 0 - 255 Normal/Red/Blue/Yellow/Green
6 Green Gain Green Gain Setting 128/97/96/96/100 0 - 255 Normal/Red/Blue/Yellow/Green
7 Blue Gain Blue Gain Setting 128/128/107/155/132 0 - 255 Normal/Red/Blue/Yellow/Green
8 Table Uniformity adjustment table setting 0 0 - 7
Group 205 Spread Spectrum
0 Enable Spread ON/OFF 1 0 - 1 0 : ON 1 : OFF
1 Modulation Frequency Modulation ratio 80 1 - 500 x 100Hz
2 Spread ratio 100 0 -300 (Set value 100 ---> 0.5%)
Group 210 LampContorl
0 DIMMER_CTRL_LEVEL1
Luminance Level 1 Data for Dimmer:
Dim Level 1 at the less than the
Value
7 0 - 255
1 DIMMER_CTRL_LEVEL2
Luminance Level 2 Data for Dimmer:
Dim Level 2 at the less than the
Value
14 0 - 255
2 DIMMER_CTRL_LEVEL3
Luminance Level 3 Data for Dimmer:
Dim Level 3 at the less than the
Value
21 0 - 255
3 DIMMER_CTRL_LEVEL4
Luminance Level 4 Data for Dimmer:
Dim Level 4 at the less than the
Value
28 0 - 255
4 DIMMER_CTRL_LEVEL5
Luminance Level 5 Data for Dimmer:
Dim Level 5 at the less than the
Value
35 0 - 255
5 DIMMER_CTRL_LEVEL6
Luminance Level 6 Data for Dimmer:
Dim Level 6 at the less than the
Value
42 0 - 255
6 DIMMER_CTRL_LEVEL7
Luminance Level 7 Data for Dimmer:
Dim Level 7 at the less than the
Value
49 0 - 255
7 DIMMER_CTRL_LEVEL8
Luminance Level 8 Data for Dimmer:
Dim Level 8 at the less than the
Value
56 0 - 255
8 DIMMER_CTRL_LEVEL9
Luminance Level 9 Data for Dimmer:
Dim Level 9 at the less than the
Value
63 0 - 255
9 DIMMER_CTRL_LEVEL10
Luminance Level 10 Data for
Dimmer: Dim Level 10 at the less
than the Value
70 0 - 255
10 DIMMER_CTRL_LEVEL11
Luminance Level 11 Data for
Dimmer: Dim Level 11 at the less
than the Value
77 0 - 255
11 DIMMER_CTRL_LEVEL12
Luminance Level 12 Data for
Dimmer: Dim Level 12 at the less
than the Value
84 0 - 255
12 DIMMER_CTRL_LEVEL13
Luminance Level 13 Data for
Dimmer: Dim Level 13 at the less
than the Value
91 0 - 255
13 DIMMER_CTRL_LEVEL14
Luminance Level 14 Data for
Dimmer: Dim Level 14 at the less
than the Value
98 0 - 255
14 DIMMER_CTRL_LEVEL15
Luminance Level 15 Data for
Dimmer: Dim Level 15 at the less
than the Value
105 0 - 255

Table of Contents