Service Adjustment
Group/
Item
Item Name Function Initial Range Note
207 C0lshd Level R max
341
0-511
208 C0lshd Level G min
200
0-511
209 C0lshd Level G
232
0-511
210 C0lshd Level G
280
0-511
211 C0lshd Level G max
334
0-511
212 C0lshd Level B min
201
0-511
213 C0lshd Level B
232
0-511
214 C0lshd Level B
290
0-511
215 C0lshd Level B max
350
0-511
250 ODS Test Pattern
0
0-6
Group 101 : Panel Service (CXA7009)
0 FRINV 0 0-1
1 SIG Center 32 0-63
2 Gain Control 194 0-255
3 Bright Control 0 0-255
4 VCOM Control R 93 0-127
5 VCOM Control G 90 0-127
6 VCOM Control B 90 0-127
7 SID Control A 18 0-255
8 SID Control B 154 0-255
Group 200 Option
0
Logo Prohibition (Forced No
Brand)
Logo Prohibition (0: Menu, 1: Forced,
3-9: not used)
0 0 - 1 Eective after AC On
1 RS232C Baudrate Baud Rate 0 0 - 2
0: 19200bps, 1: 9600bps, 2:
115200bps
2 PJLink Enable PJLink
3 Shipping Setting 0 0 - 20
Default set when the value is set to
10
4 CABLE SW Long Cable 0 0 - 1 0: Disable, 1: Enable
5 PW Debug Command Enable 0 0 - 1
0:Disable (Serial Command Eanble)
1: Enable (PW Debug Mode)
6 Device Refresh Disable 0 0 - 1
0:Enable, 1:Disable
No last memory
7 Device Access Disable 0 0 - 1
0:Enable (Normal), 1:Disable
No last memory
50 Lamp Replacement Display Lamp Warning Display On / O 1 0 - 1 1: On, 0: O
51 Filter Warning Display Filter Warning Display On / O 1 0 - 1 1: On, 0: O
52 Lamp Counter reset Times Reset Times of Lamp Counter 0 0 - 255 Read only
53 Filter Counter Reset Time Reset Times of Filter Counter 0 0 - 255 Read only
54 Factory Default Execute Times Reset times of Fanctory Default 0 0 - 255 Read only
56 Menu Position Move menu (X asis) 0 0 - 1024
57 Menu Position Move menu (Y asis) 0 0 - 1024
59 Source Search Enable Source Search 0 0 - 1 0:Disable 1: Enable
70 RC Mode Setting RC Mode 0 0 - 1
0: Normal RC Mode
1: Promethean RC Mpde
71 Force Model Option Model Option Force Setting 0 0 - 2
0: Normal 1: Force for XE50 2: Force
for XL50,51
80 Panel life test mode Setting panel life test mode 1 0 - 1 0: Life test mode 1: Normal
Group 201 Option (signal)
0 FrameLock Option 1 0 - 1
0: FrameLockOFF at PC signal
1: FrameLockON at PC signal and
47Hz (Vfreq) ~ Panel frequency of
input signal
1 AV TRUE Change AV Signal True 0 0 - 1 0: Disable 1: Enable
2 Field Sense Invert Enable 0 0 - 1
Reverse Processing of FLDINVSetting
Value
0: Disable - Used FLDINV Setting
Value
1: Enable - Used Reversed FLDINV
Setting Value

Table of Contents

Other manuals for Sanyo PLC-XL51A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sanyo PLC-XL51A and is the answer not in the manual?

Sanyo PLC-XL51A Specifications

General IconGeneral
BrandSanyo
ModelPLC-XL51A
CategoryProjector
LanguageEnglish

Related product manuals