-55-
Electrical Adjustment
Grp / No. Item Function Range Initial Note
253 (XM150) Fan Temp Error Setting (Memorized) Normal Ceiling Top Bottom
5 Temp A Warning (Normal) Temp A (Room) to judge the Temp Error at Normal 30-100 47 48 46 46
6 Temp B Warning (Normal) Temp B (Lamp) to judge the Temp Error at Normal 30-100 71 73 71 71
7 Temp C Warning (Normal) Temp C (Panel) to judge the Temp Error at Normal 30-100 65 67 65 64
8 Temp B-A Warning (Normal) Temp B - A (Filter Clogged) to judge the Temp Error at Normal 0-100 100 100 100 100
9 Temp C-A Warning (Normal) Temp C - A (Filter Clogged) to judge the Temp Error at Normal 0-100 100 100 100 100
10 Temp A Warning (Eco) Temp A (Room) to judge the Temp Error at Eco 30-100 48 48 46 46
11 Temp B Warning (Eco) Temp B (Lamp) to judge the Temp Error at Eco 30-100 71 73 71 71
12 Temp C Warning (Eco) Temp C (Panel) to judge the Temp Error at Eco 30-100 65 65 63 63
13 Temp B-A Warning (Eco) Temp B - A (Filter Clogged) to judge the Temp Error at Eco 0-100 100 100 100 100
14 Temp C-A Warning (Eco) Temp C - A (Filter Clogged) to judge the Temp Error at Eco 0-100 100 100 100 100
15 Temp A Warning Offset (Temp)
Temp Warning Offset (Temp)
0-100 10
16 Temp B Warning Offset (Temp) 0-100 11
17 Temp C Warning Offset (Temp) 0-100 13
18 Temp B-A Warning Offset (Temp) 0-100 11
19 Temp C-A Warning Offset (Temp) 0-100 13
20 Temp A Warning Offset (Time)
Time Warning Offset (Time)
0-40 30
21 Temp B Warning Offset (Time) 0-40 25
22 Temp C Warning Offset (Time) 0-40 30
23 Temp B-A Warning Offset (Time) 0-40 15
24 Temp C-A Warning Offset (Time) 0-40 15
253 (XM100) Fan Temp Error Setting (Memorized) Normal Ceiling Top Bottom
5 Temp A Warning (Normal) Temp A (Room) to judge the Temp Error at Normal 30-100 48 47 47 47
6 Temp B Warning (Normal) Temp B (Lamp) to judge the Temp Error at Normal 30-100 70 70 70 70
7 Temp C Warning (Normal) Temp C (Panel) to judge the Temp Error at Normal 30-100 65 65 65 65
8 Temp B-A Warning (Normal) Temp B - A (Filter Clogged) to judge the Temp Error at Normal 0-100 100 100 100 100
9 Temp C-A Warning (Normal) Temp C - A (Filter Clogged) to judge the Temp Error at Normal 0-100 100 100 100 100
10 Temp A Warning (Eco) Temp A (Room) to judge the Temp Error at Eco 30-100 47 48 47 47
11 Temp B Warning (Eco) Temp B (Lamp) to judge the Temp Error at Eco 30-100 68 69 68 68
12 Temp C Warning (Eco) Temp C (Panel) to judge the Temp Error at Eco 30-100 63 64 63 63
13 Temp B-A Warning (Eco) Temp B - A (Filter Clogged) to judge the Temp Error at Eco 0-100 100 100 100 100
14 Temp C-A Warning (Eco) Temp C - A (Filter Clogged) to judge the Temp Error at Eco 0-100 100 100 100 100
15 Temp A Warning Offset (Temp)
Temp Warning Offset (Temp)
0-100 10
16 Temp B Warning Offset (Temp) 0-100 11
17 Temp C Warning Offset (Temp) 0-100 13
18 Temp B-A Warning Offset (Temp) 0-100 11
19 Temp C-A Warning Offset (Temp) 0-100 13
20 Temp A Warning Offset (Time)
Time Warning Offset (Time)
0-40 30
21 Temp B Warning Offset (Time) 0-40 25
22 Temp C Warning Offset (Time) 0-40 30
23 Temp B-A Warning Offset (Time) 0-40 15
24 Temp C-A Warning Offset (Time) 0-40 15
Top
70°
290°
110°
250°
Bottom
Ceiling
Normal
254 (XM150) Fan Control Range Setting (Temp/Spinning) Normal Ceiling Top Bottom
16 Normal Fan Control Min Temp
Temp Sensor Control Start/End Temp at Normal
20-100 25 26 25 26
17 Normal Fan Control Max Temp 20-100 37 37 36 36
18 Normal Fan1 Min
Fan Spinning Set at Normal (Min/Max) (0.1V)
0000-9990 70 70 70 70
19 Normal Fan1 Max 0000-9990 138 138 138 138
20 Normal Fan2 Min 0000-9990 60 60 60 60
21 Normal Fan2 Max 0000-9990 138 138 138 138
22 Normal Fan3 Min 0000-9990 35 55 55 35
23 Normal Fan3 Max 0000-9990 35 60 60 35
24 Normal Fan4 Min 0000-9990 60 60 60 60
25 Normal Fan4 Max 0000-9990 138 138 138 138
26 Normal Fan5 Min 0000-9990 70 70 70 70
27 Normal Fan5 Max 0000-9990 100 100 100 100
28 Normal Fan6 Min 0000-9990 55 35 35 60
29 Normal Fan6 Max 0000-9990 55 35 45 60
30 Normal Fan7 Min 0000-9990 56 56 65 56
31 Normal Fan7 Max 0000-9990 98 98 98 98