1. OPERATING RANGE
1
Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp.
Cooling
Maximum 95°F D.B. / 71°F W.B. 115°F D.B.
Minimum 67°F D.B. / 57°F W.B. 67°F D.B.
Heating
Maximum 80°F D.B. / 67°F W.B.
Minimum — D.B. / — W.B.
HEAT PUMP MODEL
Model STW * * * * H2
Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp.
Cooling
Maximum 95°F D.B. / 71°F W.B. 115°F D.B.
Minimum 67°F D.B. / 57°F W.B. 67°F D.B.
Heating
Maximum 80°F D.B. / 67°F W.B. 75°F D.B. / 65°F W.B.
Minimum — D.B. / — W.B. 17°F D.B. / 15°F W.B.
COOLING & ELECTRIC HEATING MODEL
Models STW * * * * C2